WavePro HD Oscilloscopes
분    류웨이브프로 고화질 오실로스코프
모델명WavePro 804HD-MS
DATA SHEET 

상품상세 정보

          
Key Features
  • HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s
  • Up to 5 Gpts of acquisition memory enables detailed viewing of long events
  • 15.6" 1900 x 1080 Full HD capacitive touchscreen
  • New ProBus2 input supports up to 8 GHz bandwidth and direct compatibility with a wide variety of existing ProBus probes - 50Ω and 1MΩ coupling modes support all input types on a single connector
  • MAUI with OneTouch user interface for intuitive and efficient operation
  • Deep toolbox enables and simplifies complex analysis
  • Intuitive navigation to quickly find important features in long waveforms

 

HD4096 High Definition Technology

Next-generation Teledyne LeCroy HD4096 technology enables capture and display of signals with 16 times more resolution than other oscilloscopes, up to 8 GHz bandwidth and 20 GS/s sample rate. Waveforms captured and displayed are cleaner and crisper. Signal details often lost in the noise on other oscilloscopes are clearly visible and easy to distinguish with HD4096. HD4096 enables oscilloscopes to deliver unmatched measurement precision for improved debug and analysis. High-resolution performance comes with no special operating modes or compromises on bandwidth or sample rate.

5 Gpt Acquisition Memory

With up to 5 Gpts of acquisition memory, WavePro HD 12-bit oscilloscopes capture events occurring over long periods of time, while still maintaining high sample rate for visibility into the smallest details. A sophisticated acquisition and memory management architecture makes even the longest acquisitions fast and responsive. WavePro HD can capture 250 ms of data at full 20 GS/s sample rate - and always with 12 bits of resolution. Oscilloscopes with less memory require trading off sample rate for acquisition time.

Powerful, Deep Toolbox

WavePro HD features the comprehensive toolset common to all Teledyne LeCroy oscilloscopes. Measurements, math functions, analysis packages and advanced documentation features are all tightly integrated, and simple to use both independently and as part of a more sophisticated measurement setup.

ProBus2 Probe Interface

To fully realize the benefits of 8 GHz bandwidth at 12-bit resolution, WavePro HD features the ProBus2 probe interface. Based around a fully BNC-compatible connector with 8 GHz bandwidth, ProBus2 inputs can accept new ProBus2 probes up to 8 GHz, direct 50Ω coaxial connections, a wide variety of existing ProBus voltage and current probes, and passive probes requiring 1MΩ coupling.

Deeply Embedded Computing Systems Testing

WavePro HD has unsurpassed capabilities to acquire the longest records at the highest resolution for the most comprehensive deeply embedded computing system (analog, digital, serial data and sensor) testing. Comprehensive low-speed serial data triggers and decoders, plus measure/ graph and eye diagram testing provide the best causal analysis.

Power Integrity Test

WavePro HD's combination of high bandwidth and high resolution provides the capability to validate and debug all aspects of power supply, delivery and consumption - ensuring complete confidence. High bandwidth means accurate characterization of high-speed on-die effects such as ground bounce, while exceptionally low noise enables identification and root-cause analysis of low-level noise sources. Sensitive measurements such as rail collapse characterization can be made with complete confidence thanks to WavePro HD's high dynamic range and 0.5% gain accuracy.

Serial Data Jitter and Noise Analysis

WavePro HD 12-bit oscilloscopes bring the high signal fidelity of HD4096 technology to high-speed serial data analysis. 12-bit resolution, exceptionally low noise and 60 fs timebase jitter mean a low jitter measurement floor, for the most accurate serial data jitter and noise measurements possible. SDAIII CompleteLinQ provides the most complete set of serial data analysis tools available, and user-friendly QualiPHY options greatly simplify complex compliance testing.

Electromagnetic Compatibility (EMC/EMI)

WavePro HD 12-bit oscilloscopes' high sample rate and long memory combine with Teledyne LeCroy's dedicated EMC pulse parameter package to accurately characterize EMC test signals. Fast pulse rise times may require 2.5 to 4 GHz bandwidth at very high sample rates to ensure measurement confidence. WavePro HD provides the most accurate characterization using 20 GS/s sample rate, 12-bit resolution, and 0.5% gain accuracy.





Vertical - Analog Channels

Analog Bandwidth (Max)8 GHz on 2 Ch
4 GHz on 4 Ch
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input)500 MHz (typical)
Rise Time (10-90%, 50 Ω)57.5 ps
Rise Time (20-80%, 50 Ω)40.5 ps
Input Channels4
Vertical Resolution12 bits; up to 15 bits with enhanced resolution (ERES)
Effective Number of Bits (ENOB)7.0 bits
Vertical Noise Floor (1 mV/div)315 µV
Vertical Noise Floor (2 mV/div)315 µV
Vertical Noise Floor (5 mV/div)315 µV
Vertical Noise Floor (10 mV/div)315 µV
Vertical Noise Floor (20 mV/div)420 µV
Vertical Noise Floor (50 mV/div)983 µV
Vertical Noise Floor (100 mV/div)1.95 mV
Vertical Noise Floor (200 mV/div)3.16 mV
Vertical Noise Floor (500 mV/div)7.76 mV
Vertical Noise Floor (1 V/div)13.81 mV
Sensitivity50 Ω: 1 mV-1 V/div, fully variable;
1 MΩ: 1 mV-10 V/div, fully variable
DC Vertical Gain Accuracy (Gain Component of DC Accuracy)±(0.5%) F.S, offset at 0 V
Channel-Channel Isolation70dB up to 200 MHz
60dB up to 500 MHz
50dB up to 1 GHz
40dB up to 2.5 GHz
30dB up to 8 GHz
Offset Range50 Ω, ≤1 GHz BWL
1mV-4.95mV: +/-1.6V
5mV-9.9mV: +/-4V
10mV-19.8mV: +/-8V
20mV-1V: +/-10V

50 Ω, >1 GHz BWL
1mV/div-34.5mV/div: +/- 0.5V
35mV/div-87mV/div: +/- 1.25V
88mV/div-220mV/div: +/-3V
225mV/div-1V/div: +/-5V

1 MΩ
1mV-4.95mV: +/-1.6V
5mV-9.9mV: +/-4V
10mV-19.8mV: +/-8V
20mV-100mV: +/-16V
102mV-198mV: +/-80V
200mV-1V: +/-160V
1.02V-10V: +/-400V
DC Vertical Offset Accuracy+/-(0.5% of offset value + 0.5%FS + 1mV)
Maximum Input Voltage50 Ω, ≤1 GHz BWL
5V RMS, +/- 10V Peak

50 Ω, >1 GHz BWL
'+/-2V max. up to 34.5mV/div
+/-5V max. 35mV/div to 87mV/div
5.5Vrms >87mV/div

1 MΩ
400 V max
(Peak DC+AC)
Input Coupling1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Input Impedance50 Ω+/-2% or 1 MΩ||14pF, 10 MΩ || 9.5 pF
Bandwidth Limiters20MHz, 200MHz, 500 MHz, 1 GHz, 2.5 GHz, 4 GHz, 6 GHz
RescalingLength: meters, inches, feet, yards, miles; Mass: grams, slugs; Temperature: celsius, fahrenheit, kelvin; Angle: radian, arcdegr, arcmin, arcsec, cycles, revolutions, turns; Velocity: m/s, in/s, ft/s, yd/s, miles/s; Acceleration: m/s2, in/s2, ft/s2, g0; Volume: liters, cubic meters, cubic inches, cubic feet, cubic yards; Force (Weight): newton, grain, ounce, pound; Pressure: pascal, bar, atmosphere (technical), atmosphere (standard), torr, psi; Electrical: volts, amps, watts, volt-amperes, volt-amperes reactive, farad, coulomb, ohm, siemen, volt/meter, coulomb/m2, farad/meter, siemen/meter, power factor; Magnetic: weber, tesla, henry, amp/meter, henry/meter; Energy: joule, Btu, calorie; Rotating Machine: radian/second, frequency, revolution/second, revolution/minute, N?m, lb-ft, lb-in, oz-in, watt, horsepower; Other: %.
 

Horizontal - Analog Channels

TimebasesInternal timebase common to 4 input channels
Acquisition ModesReal-time
Time/Division Range20ps/div - 1 ks/div
Clock Accuracy+/-100ppb for 5 to 40C + 0.10ppm/year from calibration
Sample Clock Jitterup to 10µs Acquired Time Range:
60 fsrms (Internal Timebase Reference)

up to 10ms Acquired Time Range:
100 fsrms (Internal Timebase Reference)
Delta Time Measurement Accuracy\sqrt{2}*\sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2) (RMS)+(clock accuracy*reading)(seconds)
Jitter Measurement Floor\sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2\; seconds\; rms\; (TIE)}
Channel-Channel Deskew Range±9 x time/div. setting, 100 ms max., each channel
External Timebase Reference (Input)10MHz +/-25ppm at 0 to 10dBm into 50Ohms
External Timebase Reference (Output)10MHz, 5.0 dBm +/-2.5 dBm, sinewave synchronized to reference being used (internal or external reference)
External ClockN/A
 

Acquisition - Analog Channels

Sample Rate (Single-shot)10 GS/s on 4 Ch
20 GS/s on 2 Ch
Sample Rate (Repetitive)N/A
Memory Length (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
50M/100M (65,536)
Memory Length Options (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
WPHD-200MPT Option:
100M / 200M (65,535)
WPHD-500MPT Option:
250M / 500M (65,535)
WPHD-1000MPT Option:
500M / 1000M (65,535)
WPHD-2000MPT Option:
1000M / 2000M (65,535)
WPHD-5000MPT Option:
2500M / 5000M (65,535)

Maximum analysis memory: 500 Mpts per channel
Intersegment Time1.5 us
AveragingSummed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
(Waveforms of ≤500Mpts)
Envelope (Extrema)Envelope, floor, or roof for up to 1 million sweeps
(Waveforms of ≤500Mpts)
InterpolationLinear or Sin x/x (2 pt and 5 pt)
(Waveforms of ≤500Mpts)
 

Vertical, Horizontal, Acquisition - Digital Channels

Maximum Input Frequency250 MHz
Minimum Detectable Pulse Width2 ns
Input Channels16 Digital channels
Input Impedance (Flying Leads)100 kΩ || 5 pF
Input Dynamic Range± 20V
Maximum Input Voltage±30V Peak
Maximum Input Voltage Swing400mV
Threshold GroupingsPod 2: D15 - D8, Pod 1: D7 - D0
Threshold SelectionsTTL, ECL, CMOS (2.5 V, 3.3 V, 5 V), PECL, LVDS or User Defined
Threshold Accuracy±(3% of threshold setting + 100mV)
User Defined Threshold Range±10 V in 20 mV steps
User Defined Hysteresis Range100 mV to 1.4 V in 100 mV steps
Sample Rate1.25 GS/s
Record LengthStandard:
50M
WPHD-200MPT Option:
100M
WPHD-500MPT Option:
125M
WPHD-1000MPT Option:
125M
WPHD-2000MPT Option:
125M
WPHD-5000MPT Option:
125M
Channel-to-Channel Skew350ps
 

Triggering System

Modes Acquisition of ≤500Mpts:
Normal, Auto, Single, and Stop

Acquisition of >500Mpts:
Single
SourcesAny input channel, Ext, Ext/10, Line, or Fast Edge; slope and level unique to each source (except Line and Fast edge)
CouplingDC, AC, HFRej, LFRej
Pre-trigger Delay0-100% of memory size
Post-trigger DelayNo limitation
Hold-offFrom 1 ns up to 20 s or from 1 to 99,999,999 events
Trigger and Interpolator Jitter≤ 2.5 ps RMS (typical)
<0.1 ps RMS (typical, software assisted)
Internal Trigger Level Range±4.1 div from center (typical)
External Trigger Level RangeExt (±0.4 V); Ext/10 (±4 V)
Maximum Trigger Rate650,000 waveforms/second (in Sequence Mode, up to 4 channels)
Trigger Sensitivity with Edge Trigger ProBus Inputs2.25 div @ < 8 GHz
1.25 div @ < 4.5 GHz
0.75 div @ < 1 GHz
Trigger Sensitivity with Edge Trigger (Aux Input)0.5 div @ < 1 GHz
Max. Trigger Frequency, SMART Trigger 2.0 GHz @ ≥ 10 mV/div
(minimum triggerable width 200 ps)
 

Trigger Types

EdgeTriggers when signal meets slope (positive, negative, or either) and level condition.
WidthTriggers on positive or negative glitches with selectable widths.
Minimum width 500 ps, maximum width: 20 s
GlitchTriggers on positive or negative glitches with selectable widths. Minimum width 200 ps, maximum width: 20 s
WindowTriggers when signal exits a window defined by adjustable thresholds
PatternLogic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
TV-Composite VideoTriggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
RuntTrigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew RateTrigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
IntervalTriggers on intervals selectable between 1 ns and 20 s.
DropoutTriggers if signal drops out for longer than selected time between 1 ns and 20 s.
Measurement TriggerSelect from a large number of measurement parameters trigger on a measurement value with qualified limits. Can be used as only trigger or last event in a Cascade Trigger.
Multi-Stage: Qualified (Timeout or State/Edge Qualified)Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events. (Note: event B pattern trigger cannot include analog channels).
Triggers with Exclusion TechnologyTrigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
Multi-Stage: Qualified FirstIn Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events. (Note: event B pattern trigger cannot include analog channels).
TriggerScanA Trigger Trainer analyzes the waveforms, identifies normal behavior, and then sets up a large set of rare event smart trigger setups that target abnormal behavior. The trainer ‘learns’ trigger setups based on slew rates, periods, amplitudes outside of a range and then applies them sequentially.
 

Low Speed Serial Protocol Trigger (Optional)

Supported ProtocolsI2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN1.1, CAN2.0, CAN FD, LIN, FlexRay, MIL-STD-1553
 

Measurement Tools

Measurement FunctionalityDisplay up to 12 measurement parameters together with statistics, including mean, minimum, maximum, standard deviation, and total number. Each occurrence of each parameter is measured and added to the statistics table. Histicons provide a fast, dynamic view of parameters and waveshape characteristics. Parameter math allows addition, subtraction, multiplication, or division of two different parameters. Parameter gates define the location for measurement on the source waveform. Parameter accept criteria define allowable values based on range setting or waveform state.
Measurement Parameters - Horizontal + JitterCycles (number of), Delay (from trigger, 50%), Δ Delay (50%), Duty Cycle (50%, @level), Edges (number of, @level), Fall Time (90-10, @levels), Frequency (50%, @level), Half Period (@level), Hold Time (@level), N Cycle Jitter (peak-peak), Number of Points, Period (50%, @level), Δ Period (@level), Phase (@level), Rise Time (10-90, @levels), Setup (@levels), Skew (@levels), Slew Rate (@levels), Time Interval Error (@level), Time (@level), Δ Time (@level), Width (50%, @level), Δ Width (@level), X(value)@max, X(value)@min
Measurement Parameters - VerticalAmplitude, Base, Level@X, Maximum, Mean, Median, Minimum, Peak-to-Peak, RMS, Std. Deviation, Top.
Measurement Parameters - PulseArea, Base, Fall Time (90-10, 80-20, @levels), Overshoot (positive, negative), Rise Time (10-90, 80-20, @levels), Top, Width (50%)
Measurement Parameters - Statistical (on Histograms)Full Width (@ Half Max, @ %), Amplitude, Base, Peak @ Max Population, Maximum, Mean, Median, Minimum, Mode, Range, RMS, Std. Deviation, Top, X(value)@Peak, Peaks (number of), Percentile, Population (@bin, total)
 

Math Tools

Math FunctionalityDisplay up to 12 math functions traces (F1-F12). The easy-to-use graphical interface simplifies setup of up to two operations on each function trace, and function traces can be chained together to perform math-on-math.
Math Operators - Basic MathAverage (summed), Average (continuous), Difference (-), Envelope, Floor, Invert (negate), Product (x), Ratio (/), Reciprocal, Rescale (with units), Roof, Sum (+).
Math Operators - Digital (incl. with MSO models/options)Digital AND, Digital DFlipFlop, Digital NAND, Digital NOR, Digital NOT, Digital OR, Digital XOR
Math Operators - FiltersEnhanced resolution (to 15 bits vertical), Interpolate (cubic, quadratic, sinx/x), (SinX)/x.
Math Operators - Frequency AnalysisFFT (power spectrum, magnitude, phase, power density, real, imaginary, magnitude squared), up to full record length. Select from Rectangular, VonHann, Hamming, FlatTop and Blackman Harris windows.
Math Operators - FunctionsAbsolute value, Correlation (two waveforms), Derivative, Deskew (resample), Exp (base e), Exp (base 10), Integral, Invert (negate), Log (base e), Log (base 10), Reciprocal, Rescale (with units), Square, Square root, Zoom (identity).
Math Operators - OtherSegment, Sparse
 

Measurement and Math Integration

Measurement and Math IntegrationHistograms to display statistical distributions of up to 2 billion measurement parameters. Trend (datalog) of up to 1 million measurement parameters. Track (display parameter vs. time, time-correlated to acquisitions) any parameter. Persistence histogram and persistence trace (mean, range, sigma)
 

Pass/Fail Testing

Pass/Fail TestingDisplay up to 12 pass/fail queries using a Single or Dual Parameter Comparison (compare All values, or Any value <. ≤, =, >, ≥, within limit ±Δ value or %) or Mask Test (pre-defined or user-defined mask, waveform All In, All Out, Any In, or Any Out conditions). Combine queries into a boolean expression to Pass or Fail IF "All True", "All False", "Any True", "Any False", or groups or "All" or "Any", with following THEN Save (waveforms), Stop, Alarm, (send) Pulse, Hardcopy (send email, save screen image, save to clipboard, send to printer), or (save) LabNotebook.
 

Display System

SizeColor 15.6" widescreen capacitive touch screen
Resolution1920 x 1080 pixels
Number of tracesDisplay a maximum of 40 traces. Simultaneously display channel, zoom, memory and math traces.
Grid StylesAuto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y, Tandem, Quatro, Twelve, Sixteen
Waveform RepresentationSample dots joined, or sample dots only
 

Persistence Display

Analog and Color-Graded PersistenceWaveforms of ≤500Mpts:
Variable saturation levels; stores each trace’s persistence data in memory
Persistence TypesWaveforms of ≤500Mpts:
Select analog, color, or three-dimensional
Trace SelectionWaveforms of ≤500Mpts:
Activate persistence on all or any combination of traces
Persistence AgingWaveforms of ≤500Mpts:
Select from 500 ms to infinity
Sweep Display ModesWaveforms of ≤500Mpts:
All accumulated, or all accumulated with last trace highlighted
 

Zoom Expansion Traces

Zoom Expansion TracesDisplay up to 12 Zoom and 12 Math/Zoom traces
 

Internal Waveform Memory

Internal Waveform Memory12 active waveform memory traces (M1-M12) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
 

Setup Storage

Front Panel and Instrument StatusStore to the internal hard drive, over the network, or to a USB-connected peripheral device.
 

Automatic Setup

Auto SetupAutomatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical ScaleAutomatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

Calibration

Auto CalibrationEnsures specified DC and timing accuracy is maintained for 1 year minimum.
 

Processor/CPU

TypeIntel® Core i5-6500 Quad Core, 3.2 GHz (or better)
Processor Memory16 GB standard
Operating SystemMicrosoft Windows® 10
Oscilloscope Operating SoftwareTeledyne LeCroy MAUI™ with OneTouch
Real Time ClockDate and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Connectivity

Ethernet Port2 x 10/100/1000BaseT Ethernet interface (RJ45 port)
USB Host Ports4 side USB 3.1 Gen1 ports, 3 front USB 3.1 Gen1 ports
USB Device Port1 port - USBTMC over USB 3.1 Gen1
GPIB Port (optional)Supports IEEE - 488.2 (External)
External Monitor Port1 x DisplayPort, supports up to 4096x2304 @ 24 Hz
1 x HDMI, supports up to 4096x2304 @ 60 Hz
Remote ControlVia Windows Automation, or via LeCroy Remote Command Set
Network Communication StandardVXI-11 or VICP, LXI Compatible
 

Auxiliary Input

Signal TypesFor external trigger input
Coupling50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage50 Ω
5V RMS, +/- 10V Peak

1 MΩ
400 V max (Peak DC+AC)
 

Auxiliary Output

Signal TypesSelect from outpout signal, control signals, off
Output Signal500 Hz-5 MHz square wave or DC level; 50 mV-1 V into 1 MΩ
Control SignalsTrigger enabled, trigger out, pass/fail status, fast edge, off
Connector TypeBNC, located on front
 

Probes

Probes Qty. (4) ÷10 Passive Probes
Probe SystemProBus2. Automatically detects and supports a variety of compatible probes.
Fully backwards-compatible to ProBus probes without the use of adapters.
Scale FactorsAutomatically or manually selected depending on probe used
Calibration OutputDefault is 1kHz square wave, 1Vp-p (typical), output to probe hook. Settable from 500 Hz to 1 MHz square wave; 50 mV to 1.0V.
 

Power Requirements

Voltage 90 - 132 Vrms, 380 - 420Hz
90 - 264 Vrms, 47 - 63 Hz
Nominal Power Consumption400W/400VA
Max. Power Consumption525W/525VA
 

Certifications

CertificationsCE Compliant, UL and cUL listed; conforms to
UL 61010-1 (3rd Edition), UL 61010-2-030 (1st Edition)
CAN/CSA C22.2 No. 61010-1-12
 

Environmental

Temperature (Operating)+5 °C to +40 °C
Temperature (Non-Operating)-20 °C to +60 °C
Humidity (Operating)5% to 90% relative humidity (non-condensing) up to +31 °C.
Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
Humidity (Non-Operating)5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating)Up to 10,000 ft. (3048 m) at or below +30 °C
Altitude (Non-Operating)Up to 40,000 ft. (12,192 m)
Random Vibration (Operating)0.31 grms 5 Hz to 500 Hz, 20 minutes in each of three orthogonal axes
Random Vibration (Non-Operating)2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock30 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Size and Weight

Dimensions (HWD)13.6” H x 17.5” W x 7.7” D (345 x 445 x 196 mm)
Weight24.4 lbs (11.1 kg)
Shipping Weight34 lbs
 

Warranty and Service

Warranty and Service

3-year warranty; calibration recommended annually.
Optional service programs include extended warranty, upgrades, and calibration services.