분    류Disk Drive Analyzer
모델명DDA 808Zi-B
DATA SHEET 

상품상세 정보

          
Key Features
  • Up to 30 GHz bandwidth and 80 GS/s sample rate
  • The most advanced oscilloscope user interface
  • The industry’s only true hardware 14.1 Gb/s serial trigger
  • Low Jitter Measurement Floor and exceptional timebase stability
  • Comprehensive set of serial data analysis, debug, validation and compliance tools
  • Integrated 50 Ω and 1 MΩ inputs for true connection and probing flexibility
  • Integrated standard and custom measurements and math functions for unrivaled analysis capability
  • Multi-lane serial data eye, jitter and crosstalk analysis
  • Real-time de-embedding, emulation, and equalization
Exceptional Performance

With up to 30 GHz bandwidth, 80 GS/s sample rate, extremely stable timebase and a 14.1 Gb/s serial trigger the WaveMaster 8 Zi-B has the hardware performance to capture today’s high-speed signals.

Revolutionary Usability

The WaveMaster 8Zi-B is a sophisticated instrument, designed for solving complex problems. But the MAUI user interface, along with the WaveMaster 8Zi-B’s 15.3” high-resolution touchscreen, makes advanced analysis easy to set up and use. A flat menu structure puts the most common tools in the easiest reach. Sophisticated multi-grid displays are easy to configure. Vertical, horizontal and acquisition setting changes are made without obscuring waveform display.

Made to Solve

MAUI provides the most tightly-integrated toolset of any oscilloscope user interface. Track measured parameters across acquisitions, trend their variations on longer timescales, or visualize and measure their distributions using histograms. Chain multiple measurements and math functions together to easily create custom analysis features for your applications. Integrate third-party programming environments, such as MATLAB, directly into the scope’s processing stream for even more customization.

Debug and Validation Made Easy

Connecting a problem with its root cause often requires looking at the signal in multiple domains. The WaveMaster 8Zi-B allows you to combine multiple analysis types into a single, correlated display: analog signals, protocol decodes, eye diagrams, measurement parameters, and other relevant information are presented side-by-side, in real-time.

Configurations Optimized for Serial Data Analysis

The SDA 8 Zi-B models have been specifically configured to handle today’s most challenging serial data applications. As well as doubling the standard memory depth, the SDA 8 Zi-B comes as standard with a 6.5 Gb/s true hardware serial pattern trigger, and the SDAIII core toolset, which provides tightly-integrated and comprehensive eye diagram and jitter analysis for NRZ signals.

SDAIII toolset

The Teledyne LeCroy SDAIII-CompleteLinQ Serial Data Analysis products contain multilane eye and jitter analysis, LaneScape™ comparison modes, vertical noise measurements, and crosstalk analysis tools. These capabilities provide the deepest insight into the behavior of multi- or single-lane serial data systems.

Decode From Bit-level to Protocol Layer

Decoders are available for over 20 low-speed and high-speed serial data buses. These fully-integrated analysis tools annotate the acquired analog waveform with the corresponding decoded data, as well as providing a comprehensive, exportable decode table.

For many standards, ProtoSync allows a view from even higher up the protocol stack, linking the physical-layer waveforms to full transaction- and protocol-layer analysis.

Automated Compliance Testing

Teledyne LeCroy’s QualiPHY software makes it easy to perform automated compliance tests and produce comprehensive test reports on a wide array of serial standards including:

  • PCI Express (1.0, 2.0, 3.0)
  • USB1, USB2, USB 3.0, USB 3.1
  • DDR2, LPDDR2, DDR3, LPDDR3, DDR4, LPDDR4
  • SAS2, SAS3, SATA
  • MIPI D-PHY, MIPI M-PHY
  • 10/100/100 BASE-T, 10GBASE-T, 10GBASE-KR, SFI
  • HDMI 1.4, HDMI 2.0, DisplayPort 1.2
  • MOST50, MOST150, BroadR-Reach






Vertical - Analog Channels

Analog Bandwidth (Max)8 GHz
Analog Bandwidth @ 50 Ω (-3 dB) (ProLink Input)8 GHz
(≥10 mV/div)
Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input)3.5 GHz
(≥10 mV/div)
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input)500 MHz (typical, ≥2 mV/div)
Rise Time (10-90%, 50 Ω)49 ps
(test limit, flatness mode)
Rise Time (20-80%, 50 Ω)37 ps
(flatness mode)
Input Channels4 (Any combination of ProLink and ProBus inputs)
Vertical Resolution8 bits; up to 11 bits with enhanced resolution (ERES)
Vertical Noise Floor (50 mV/div)1.05 mVrms (typical)
Sensitivity50 Ω (ProLink): 2 mV-1 V/div, fully variable (2-9.9 mV/div via zoom)
50 Ω (ProBus): 2 mV-1 V/div, fully variable; 1 MΩ (ProBus): 2 mV-10 V/div, fully variable
DC Vertical Gain Accuracy (Gain Component of DC Accuracy)±1% F.S. (typical), offset at 0V; ±1.5% F.S. (test limit), offset at 0V
Channel-Channel IsolationDC to 10 GHz: 50 dB (>315:1)
10 to 15 GHz: 46 dB (>200:1)
15 to 20 GHz: 40 dB (>100:1)
(For any two ProLink input channels, same or different v/div settings, typical)
Offset Range50 Ω (ProLink):
±500 mV @ 2-100 mV/div
±4 V @ >100 mV/div -1 V/div
50 Ω (ProBus):
±750 mV @ 2-100 mV/div
±4 V @ >100 mV/div -1 V/div
1 MΩ:
±1V @ 2-140 mV/div
±10V @ 142mV-1.40V/div
±100V @ 1.42V-10V/div
DC Vertical Offset Accuracy±(1.5% of offset setting + 1.5% F.S. + 1 mV) (test limit)
Maximum Input Voltage50 Ω (ProLink): ±2 Vmax@≤100mV/div, 5.5Vrms@>100mV/div
50 Ω (ProBus): ±5 Vmax, 3.5 Vrms
1 MΩ (ProBus): 250 V max. (peak AC: < 10 kHz + DC)
Input CouplingProLink Inputs - 50 Ω: DC, GND
ProBus Inputs - 1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Input ImpedanceProLink Inputs: 50 Ω+/-2% for ≤100 mV/div, 50 Ω+/-3% for >100 mV/div
ProBus Inputs: 50 Ω+/-2% or 1 MΩ||16pF, 10 MΩ || 11 pF with supplied Probe
Bandwidth Limiters20 MHz, 200 MHz, 1 GHz, 4 GHz, 6 GHz
RescalingLength: meters, inches, feet, yards, miles; Mass: grams, slugs; Temperature: celsius, fahrenheit, kelvin; Angle: radian, arcdegr, arcmin, arcsec, cycles, revolutions, turns; Velocity: m/s, in/s, ft/s, yd/s, miles/s; Acceleration: m/s2, in/s2, ft/s2, g0; Volume: liters, cubic meters, cubic inches, cubic feet, cubic yards; Force (Weight): newton, grain, ounce, pound; Pressure: pascal, bar, atmosphere (technical), atmosphere (standard), torr, psi; Electrical: volts, amps, watts, volt-amperes, volt-amperes reactive, farad, coulomb, ohm, siemen, volt/meter, coulomb/m2, farad/meter, siemen/meter, power factor; Magnetic: weber, tesla, henry, amp/meter, henry/meter; Energy: joule, Btu, calorie; Rotating Machine: radian/second, frequency, revolution/second, revolution/minute, N?m, lb-ft, lb-in, oz-in, watt, horsepower; Other: %.
 

Horizontal - Analog Channels

TimebasesInternal timebase common to 4 input channels
Time/Division Range20 ps/div-128 s/div (Real-Time Mode: 20 ps/div - 64 s/div; RIS mode: 20 ps/div - 10 ns/div, user selectable at ≤10ns/div; Roll mode: 100 ms/div up to 128 s/div, user selectable at ≥100 ms/div and ≤5 MS/s), depending on memory length
Clock Accuracy< 1 ppm + (aging of 0.5ppm/yr from last calibration)
Sample Clock Jitterup to 10µs Acquired Time Range:
100fsrms (Internal Timebase Reference)

up to 6.4ms Acquired Time Range:
150fsrms (Internal Timebase Reference)
Delta Time Measurement Accuracy\sqrt{2}*\sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2) (RMS)+(clock accuracy*reading)(seconds)
Jitter Measurement Floor\sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2\; seconds\; rms\; (TIE)}
Jitter Between Channels<425fsrms
(TIE, typical, measured at maximum bandwidth)
Channel-Channel Deskew Range±9 x time/div. setting or 25 ns max. (whichever is larger), each channel
External Timebase Reference (Input)10 MHz; 50 Ω impedance, applied at the rear input
External Timebase Reference (Output)10 MHz; 50 Ω impedance, output at the rear
 

Acquisition - Analog Channels

Sample Rate (Single-shot)40 GS/s
(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Sample Rate (Repetitive)200 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Memory Length (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
64 M / 64 M / 64 M
(Memory and Sample Rate can be doubled in 1 or 2 Ch mode with use of WM8Zi-2X80GS External Interleaving Device)
(15000)
Memory Length Options (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
L-128 Option:
128M / 128M / 128M
(15,000)
VL-256 Option:
256M / 256M / 256M
(15,000)
Note: On all memory options, WM8Zi-2X80GS External Interleaving Device permits 80 GS/s on 1 or 2ch with twice the memory)
Intersegment Time1 µs
AveragingSummed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES)From 8.5 to 11 bits vertical resolution
Envelope (Extrema)Envelope, floor, or roof for up to 1 million sweeps
InterpolationLinear or Sin x/x
 

Triggering System

Modes Normal, Auto, Single, and Stop
SourcesAny input channel, Aux, Aux/10, Line, or Fast Edge. Slope and level unique to each source (except line trigger)
CouplingDC, AC, HFRej, LFRej
Pre-trigger Delay0-100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay0-10,000 divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-offFrom 2 ns up to 20 s or from 1 to 99,999,999 events
Trigger and Interpolator Jitter<0.1 ps rms (typical, software assisted), 2 ps rms (typical, hardware),
Internal Trigger Level Range±4.1 div from center
External Trigger Level RangeAux (±0.4 V); Aux/10 (±4 V)
Maximum Trigger Rate1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
Trigger Sensitivity with Edge Trigger ProLink Inputs2 div @ < 8 GHz,
1.5 div @ < 3 GHz,
1.0 div @ < 200 MHz,
(for DC, AC, LFRej coupling, ≥ 10 mV/div, 50 Ω )
Trigger Sensitivity with Edge Trigger ProBus Inputs2 div @ < 3.5 GHz,
1.5 div @ < 1.75 GHz,
1.0 div @ < 200 MHz,
(for DC coupling, ≥ 10 mV/div, 50 Ω )
Trigger Sensitivity with Edge Trigger (Aux Input)2 div @ < 1 GHz,
1.5 div @ < 500 MHz,
1.0 div @ < 200 MHz,
(for DC coupling)
Max. Trigger Frequency, SMART Trigger 2.0 GHz @ ≥ 10 mV/div (minimum triggerable width 200 ps)
 

Trigger Types

EdgeTriggers when signal meets slope (positive, negative, or either) and level condition.
WidthTriggers on positive, negative, or both widths with widths selectable as low as 200ps to 20 s, or on intermittent faults.
GlitchTriggers on positive or negative glitches with widths selectable as low as 200ps to 20 s, or on intermittent faults.
WindowTriggers when signal exits a window defined by adjustable thresholds
PatternLogic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
TV-Composite VideoTriggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
RuntTrigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew RateTrigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
IntervalTriggers on intervals selectable between 1 ns and 20 s.
DropoutTriggers if signal drops out for longer than selected time between 1 ns and 20 s.
Measurement TriggerSelect from a large number of measurement parameters trigger on a measurement value with qualified limits. Can be used as only trigger or last event in a Cascade Trigger.
Multi-Stage: Qualified (Timeout or State/Edge Qualified)Triggers on any input source only if a defined state or edge occurred on another input source. Holdoff between sources is selectable by time or events.
Triggers with Exclusion TechnologyTrigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
Multi-Stage: Qualified FirstIn Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events.
Multi-Stage: Cascade (Sequence) Trigger, CapabilityArm on "A" event, then Trigger on "B" event. Or Arm on "A" event, then Qualify on "B" event, and Trigger on "C" event.
Multi-Stage: Cascade (Sequence) Trigger, TypesCascade A then B: Edge, Window, Pattern (Logic) Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage B only.
Cascade A then B then C (Measurement): Edge, Window, Pattern (Logic), Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage C only.
Cascade A then B then C: Edge, Window, Pattern (Logic)
Multi-Stage: Cascade (Sequence) Trigger, HoldoffHoldoff between A and B or B and C is selectable by time or number of events.
Measurement trigger selection as the last stage in a Cascade precludes a holdoff setting between the prior stage and the last stage.
 

Low Speed Serial Protocol Trigger (Optional)

Supported ProtocolsI2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN, LIN, FlexRay, I2S (Audio), MIL-1553
 

High Speed Serial Protocol Trigger

Data RatesOption WM8Zi-6GBIT-80B-8B10B-TD: 600 Mb/s to 6.5 Gb/s, Channel 4 input only
Option WM8Zi-14GBIT-80B-8B10B-TD: 600 Mb/s to 14.1 Gb/s, Channel 4 input only
Pattern Length80 bits NRZ, eight 8b/10b symbols, 64b/66b symbol
 

Display System

SizeColor 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen
ResolutionWXGA; 1280 x 768 pixels.
Number of tracesDisplay a maximum of 16 traces (up to 40 with some software options). Simultaneously display channel, zoom, memory and math traces.
Grid StylesAuto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y
Waveform RepresentationSample dots joined, or sample dots only
 

Integrated Second Display

SizeSupports touch screen integration of user-supplied second display with split-grid capability.
(Note: touch screen driver for second display may not be a Fujitsu driver)
ResolutionDetermined by display chosen by user
 

LeCroy WaveStream™ Fast Viewing Mode

OperationFront panel toggle between WaveStream ON (Analog), ON (Color) and OFF
Intensity256 Intensity Levels, 1-100% adjustable via front panel control
TypesSelect analog or color-graded
Number of Channelsup to 4 simultaneously
Max Sampling Rate40 GS/s (80 GS/s with optional WM8Zi-2X80GS external interleaving device)
Persistence AgingSelect from 500 ms to Infinity
Waveforms/second (continuous)up to 2500 Waveforms/second
 

Persistence Display

Analog and Color-Graded PersistenceVariable saturation levels; stores each trace’s persistence data in memory
Persistence TypesSelect analog, color, or three-dimensional
Trace SelectionActivate persistence on all or any combination of traces
Persistence AgingSelect from 500 ms to infinity
Sweep Display ModesAll accumulated, or all accumulated with last trace highlighted
 

High Speed Digitizer Output (Option)

TypeLeCroy LSIB
Transfer Rateup to 325 MB/s (typical)
Output ProtocolPCI Express, Gen 1 (4 lanes utilized for data transfer)
Control ProtocolTCP/IP
Command SetVia Windows Automation, or via LeCroy Remote Command Set
 

Zoom Expansion Traces

Zoom Expansion TracesDisplay up to 12 Zoom and 12 Math/Zoom traces
 

Internal Waveform Memory

Internal Waveform Memory12 active waveform memory traces (M1-M12) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
 

Setup Storage

Front Panel and Instrument StatusStore to the internal hard drive, over the network, or to a USB-connected peripheral device.
 

Automatic Setup

Auto SetupAutomatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical ScaleAutomatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

Calibration

Auto CalibrationEnsures specified DC and timing accuracy is maintained for 1 year minimum.
 

Processor/CPU

TypeIntel® CoreTM i7-4770S Quad, 3.1 GHz (up to 3.9 GHz in Turbo mode) (or better)
Processor Memory8 GB standard for STD memory (20 Mpt), S-32 and M-64 memory options
16 GB standard for L-128 and VL-256 memory options
Up to 32 GB optional
Operating SystemMicrosoft Windows® 7 Professional Edition (64-bit)
Oscilloscope Operating SoftwareTeledyne LeCroy MAUI™
Real Time ClockDate and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Connectivity

Ethernet PortSupports 10/100/1000BaseT Ethernet interface (RJ45 port)
USB Host Ports4 rear USB 3.0 ports, 3 front panel USB 2.0 ports support Windows compatible devices
GPIB Port (optional)Supports IEEE - 488.2
External Monitor PortFull-size DisplayPort connnector
Includes support for extended desktop operation with second monitor.
Remote ControlVia Windows Automation, or via LeCroy Remote Command Set
Network Communication StandardVXI-11 or VICP, LXI Class C (v1.2) Compliant
LSIB Port (optional)Supports PCIe Gen1 x4 protocol with LeCroy supplied API
Peripheral BusTeledyne LeCroy LBUS standard
 

Auxiliary Input

Signal TypesFor External Trigger Input
Coupling50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage50 Ω: 5 Vrms; 1 MΩ: 250 V (Peak AC < 10 kHz + DC)
 

Auxiliary Output

Signal TypesSelect from calibrator, control signals or Off
Output Signal500 Hz-5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0-1 V into 1 MΩ)
Control SignalsTrigger enabled, trigger out, pass/fail status, off
Connector TypeBNC, located on front
 

Probes

Probes Qty. (4) ÷10 Passive Probes
Probe SystemProbus and ProLink. Automatically detects and supports a variety of compatible probes
Scale FactorsAutomatically or manually selected depending on probe used
Calibration OutputCal Output: 1kHz square wave, 1Vp-p (typical), output to probe hook.
Fast Edge output: 5MHz square wave, 350mVp-p (typical), 50ps rise time, output to SMA connector, AC Coupled.
 

Power Requirements

Voltage 100-240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection, Installation Category II
Max. Power Consumption975 W / 975 VA
 

Certifications

CertificationsCE Compliant, UL and cUL listed; conforms to EN 61326, EN 61010-1, EN61010-2-030, UL 61010-1 3rd edition, and CSA C22.2 No. 61010-1-12
 

Environmental

Temperature (Operating)+5 °C to +40 °C
Temperature (Non-Operating)-20 °C to +60 °C
Humidity (Operating)5% to 80% relative humidity (non-condensing) up to +31 °C.
Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
Humidity (Non-Operating)5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating)Up to 10,000 ft. (3048 m) at or below +25 °C
Altitude (Non-Operating)Up to 40,000 ft. (12,192 m)
Random Vibration (Operating)0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating)2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Size and Weight

Dimensions (HWD)14"H x 18.4"W x 16"D (355 x 467 x 406 mm)
Weight51.5 lbs. (23.4 kg)
Shipping Weight70.0 lbs. (31.8 kg)
 

Warranty and Service

Warranty and Service3-year warranty; calibration recommended annually.
Optional service programs include extended warranty, upgrades, and calibration services.